SpecDirectory

ALLIED 4SHP17LE130P-**AvsBLUERIDGE BNG3A30UCN

Side-by-side heat pump comparison

ALLIED 4SHP17LE130P-**A

SEER2

15.6BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

29800BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

BLUERIDGE BNG3A30UCN

SEER2

15.3–17.2BTU/Wh

HSPF2

9.3–10.8BTU/Wh

Cooling Capacity

29000–30000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

BLUERIDGE BNG3A30UCN is 9% more efficient at 17.2 BTU/Wh versus 15.6 BTU/Wh for the ALLIED 4SHP17LE130P-**A. The BLUERIDGE BNG3A30UCN is larger at 30000 BTU/hr versus 29800 BTU/hr. BLUERIDGE BNG3A30UCN uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the BLUERIDGE BNG3A30UCN sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecALLIEDBLUERIDGE
SEER2 (best combination)(BTU/Wh)15.617.2
SEER2 (worst combination)(BTU/Wh)15.615.3
HSPF2 (best combination)(BTU/Wh)8.110.8
HSPF2 (worst combination)(BTU/Wh)8.19.3
EER2 (best combination)(BTU/Wh)12.512
COP at 5 °F2.361.97

Capacity

SpecALLIEDBLUERIDGE
Cooling Capacity (max)(BTU/hr)2980030000
Cooling Capacity (min)(BTU/hr)2980029000
Heating at 47 °F(BTU/hr)2840034000
Heating at 17 °F(BTU/hr)1880025000
Heating at 5 °F(BTU/hr)1490033200

Configuration

SpecALLIEDBLUERIDGE
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series4SHP17 SERIESBN Series
Indoor-Unit Combinations Rated15

Refrigerant

SpecALLIEDBLUERIDGE
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons