SpecDirectory

ALLIED 4SHP17LE130P-**AvsDuraSTAR DRU1H30S2A

Side-by-side heat pump comparison

ALLIED 4SHP17LE130P-**A

SEER2

15.6BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

29800BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

DuraSTAR DRU1H30S2A

SEER2

15.2–17.5BTU/Wh

HSPF2

8.1–10.2BTU/Wh

Cooling Capacity

28000–30000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

DuraSTAR DRU1H30S2A is 11% more efficient at 17.5 BTU/Wh versus 15.6 BTU/Wh for the ALLIED 4SHP17LE130P-**A. The DuraSTAR DRU1H30S2A is larger at 30000 BTU/hr versus 29800 BTU/hr. DuraSTAR DRU1H30S2A uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the DuraSTAR DRU1H30S2A sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecALLIEDDuraSTAR
SEER2 (best combination)(BTU/Wh)15.617.5
SEER2 (worst combination)(BTU/Wh)15.615.2
HSPF2 (best combination)(BTU/Wh)8.110.2
HSPF2 (worst combination)(BTU/Wh)8.18.1
EER2 (best combination)(BTU/Wh)12.511.7
COP at 5 °F2.362

Capacity

SpecALLIEDDuraSTAR
Cooling Capacity (max)(BTU/hr)2980030000
Cooling Capacity (min)(BTU/hr)2980028000
Heating at 47 °F(BTU/hr)2840034000
Heating at 17 °F(BTU/hr)1880025000
Heating at 5 °F(BTU/hr)1490032600

Configuration

SpecALLIEDDuraSTAR
Product TypeHP - Split SystemHP - Split System
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series4SHP17 SERIESDRU Series
Indoor-Unit Combinations Rated149

Refrigerant

SpecALLIEDDuraSTAR
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)