SpecDirectory

ALLIED 4SHP17LE130P-**AvsLennox MMPD030S6S-1P

Side-by-side heat pump comparison

ALLIED 4SHP17LE130P-**A

SEER2

15.6BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

29800BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Lennox MMPD030S6S-1P

SEER2

19–21.7BTU/Wh

HSPF2

9–9.5BTU/Wh

Cooling Capacity

30000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Lennox MMPD030S6S-1P is 28% more efficient at 21.7 BTU/Wh versus 15.6 BTU/Wh for the ALLIED 4SHP17LE130P-**A. The Lennox MMPD030S6S-1P is larger at 30000 BTU/hr versus 29800 BTU/hr. Lennox MMPD030S6S-1P uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088). Overall, the Lennox MMPD030S6S-1P sits higher in the category, ranking above 59% of certified air-source heat pumps.

Efficiency

SpecALLIEDLennox
SEER2 (best combination)(BTU/Wh)15.621.7
SEER2 (worst combination)(BTU/Wh)15.619
HSPF2 (best combination)(BTU/Wh)8.19.5
HSPF2 (worst combination)(BTU/Wh)8.19
EER2 (best combination)(BTU/Wh)12.512
COP at 5 °F2.361.80

Capacity

SpecALLIEDLennox
Cooling Capacity (max)(BTU/hr)2980030000
Cooling Capacity (min)(BTU/hr)2980030000
Heating at 47 °F(BTU/hr)2840034000
Heating at 17 °F(BTU/hr)1880022800
Heating at 5 °F(BTU/hr)1490027200

Configuration

SpecALLIEDLennox
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingSingle stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series4SHP17 SERIESMulti-Position Air Handler - Standard (CAC)
Indoor-Unit Combinations Rated13

Refrigerant

SpecALLIEDLennox
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)

More comparisons