ALLIED 4SHP17LE130P-**AvsTrane 5DCZ5030A1
Side-by-side heat pump comparison
ALLIED 4SHP17LE130P-**A
SEER2
15.6BTU/Wh
HSPF2
8.1BTU/Wh
Cooling Capacity
29800BTU/hr
Refrigerant
R-410A
GWP 2088 · Higher
Trane 5DCZ5030A1
SEER2
15.2BTU/Wh
HSPF2
7.2BTU/Wh
Cooling Capacity
29600BTU/hr
Refrigerant
R-454B
GWP 470 · Lower
Key differences
ALLIED 4SHP17LE130P-**A is 3% more efficient at 15.6 BTU/Wh versus 15.2 BTU/Wh for the Trane 5DCZ5030A1. The ALLIED 4SHP17LE130P-**A is larger at 29800 BTU/hr versus 29600 BTU/hr. Trane 5DCZ5030A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the ALLIED 4SHP17LE130P-**A sits higher in the category, ranking above 12% of certified air-source heat pumps.
Efficiency
| Spec | ALLIED | Trane |
|---|---|---|
| SEER2 (best combination)(BTU/Wh) | 15.6 | 15.2 |
| SEER2 (worst combination)(BTU/Wh) | 15.6 | 15.2 |
| HSPF2 (best combination)(BTU/Wh) | 8.1 | 7.2 |
| HSPF2 (worst combination)(BTU/Wh) | 8.1 | 7.2 |
| EER2 (best combination)(BTU/Wh) | 12.5 | 11.2 |
| COP at 5 °F | 2.36 | 2 |
Capacity
| Spec | ALLIED | Trane |
|---|---|---|
| Cooling Capacity (max)(BTU/hr) | 29800 | 29600 |
| Cooling Capacity (min)(BTU/hr) | 29800 | 29600 |
| Heating at 47 °F(BTU/hr) | 28400 | 28800 |
| Heating at 17 °F(BTU/hr) | 18800 | 17300 |
| Heating at 5 °F(BTU/hr) | 14900 | 14700 |
Configuration
| Spec | ALLIED | Trane |
|---|---|---|
| Product Type | HP - Split System | HP - Single Package |
| Compressor Staging | Single stage | Two-stage |
| Cold Climate Certified | No | No |
| Connected Capability | No | No |
| Series | 4SHP17 SERIES | 5DCZ5 |
| Indoor-Unit Combinations Rated | 1 | 1 |
Refrigerant
| Spec | ALLIED | Trane |
|---|---|---|
| Type | R-410A | R-454B |
| GWP Rating | R-410A (GWP:2088) | R-454B (GWP:470 | Lower GWP) |