SpecDirectory

American Standard / Mitsubishi Electric MUZ-FS18NA***vsMAINLINE MPP15AY18AJ2N

Side-by-side heat pump comparison

American Standard / Mitsubishi Electric MUZ-FS18NA***

SEER2

21BTU/Wh

HSPF2

10.7BTU/Wh

Cooling Capacity

17200BTU/hr

Cold Climate

Yes

Cold climate certified

MAINLINE MPP15AY18AJ2N

SEER2

15.2BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

17100BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

American Standard / Mitsubishi Electric MUZ-FS18NA*** is 28% more efficient at 21.0 BTU/Wh versus 15.2 BTU/Wh for the MAINLINE MPP15AY18AJ2N. The American Standard / Mitsubishi Electric MUZ-FS18NA*** is larger at 17200 BTU/hr versus 17100 BTU/hr. MAINLINE MPP15AY18AJ2N uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the American Standard / Mitsubishi Electric MUZ-FS18NA*** sits higher in the category, ranking above 25% of certified air-source heat pumps.

Efficiency

SpecAmerican Standard / Mitsubishi ElectricMAINLINE
SEER2 (best combination)(BTU/Wh)2115.2
SEER2 (worst combination)(BTU/Wh)2115.2
HSPF2 (best combination)(BTU/Wh)10.78.1
HSPF2 (worst combination)(BTU/Wh)10.78.1
EER2 (best combination)(BTU/Wh)12.511.7
COP at 5 °F22

Capacity

SpecAmerican Standard / Mitsubishi ElectricMAINLINE
Cooling Capacity (max)(BTU/hr)1720017100
Cooling Capacity (min)(BTU/hr)1720017100
Heating at 47 °F(BTU/hr)1900017100
Heating at 17 °F(BTU/hr)1280010900
Heating at 5 °F(BTU/hr)224008600

Configuration

SpecAmerican Standard / Mitsubishi ElectricMAINLINE
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesM-SeriesPerformance
Indoor-Unit Combinations Rated11

Refrigerant

SpecAmerican Standard / Mitsubishi ElectricMAINLINE
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons