SpecDirectory

Daikin RXP24AVJU*vsHisense AUWR-24U3SF2

Side-by-side heat pump comparison

Daikin RXP24AVJU*

SEER2

18.3BTU/Wh

HSPF2

9.2BTU/Wh

Cooling Capacity

21800BTU/hr

Cold Climate

Yes

Cold climate certified

Hisense AUWR-24U3SF2

SEER2

15.8–16.5BTU/Wh

HSPF2

8.4–9BTU/Wh

Cooling Capacity

21400–22000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Daikin RXP24AVJU* is 10% more efficient at 18.3 BTU/Wh versus 16.5 BTU/Wh for the Hisense AUWR-24U3SF2. The Hisense AUWR-24U3SF2 is larger at 22000 BTU/hr versus 21800 BTU/hr. Daikin RXP24AVJU* uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecDaikinHisense
SEER2 (best combination)(BTU/Wh)18.316.5
SEER2 (worst combination)(BTU/Wh)18.315.8
HSPF2 (best combination)(BTU/Wh)9.29
HSPF2 (worst combination)(BTU/Wh)9.28.4
EER2 (best combination)(BTU/Wh)10.310.1
COP at 5 °F1.802.05

Capacity

SpecDaikinHisense
Cooling Capacity (max)(BTU/hr)2180022000
Cooling Capacity (min)(BTU/hr)2180021400
Heating at 47 °F(BTU/hr)2400022000
Heating at 17 °F(BTU/hr)1660017000
Heating at 5 °F(BTU/hr)2400017700

Configuration

SpecDaikinHisense
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesAURORAUSIM
Indoor-Unit Combinations Rated12

Refrigerant

SpecDaikinHisense
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)

More comparisons