SpecDirectory

Daikin RXP24AVJU*vsMDV MOX430U-22HFN1-MR0

Side-by-side heat pump comparison

Daikin RXP24AVJU*

SEER2

18.3BTU/Wh

HSPF2

9.2BTU/Wh

Cooling Capacity

21800BTU/hr

Cold Climate

Yes

Cold climate certified

MDV MOX430U-22HFN1-MR0

SEER2

15.4BTU/Wh

HSPF2

9.2BTU/Wh

Cooling Capacity

22000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Daikin RXP24AVJU* is 16% more efficient at 18.3 BTU/Wh versus 15.4 BTU/Wh for the MDV MOX430U-22HFN1-MR0. The MDV MOX430U-22HFN1-MR0 is larger at 22000 BTU/hr versus 21800 BTU/hr. Daikin RXP24AVJU* uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088). Overall, the Daikin RXP24AVJU* sits higher in the category, ranking above 39% of certified air-source heat pumps.

Efficiency

SpecDaikinMDV
SEER2 (best combination)(BTU/Wh)18.315.4
SEER2 (worst combination)(BTU/Wh)18.315.4
HSPF2 (best combination)(BTU/Wh)9.29.2
HSPF2 (worst combination)(BTU/Wh)9.29.2
EER2 (best combination)(BTU/Wh)10.310
COP at 5 °F1.802

Capacity

SpecDaikinMDV
Cooling Capacity (max)(BTU/hr)2180022000
Cooling Capacity (min)(BTU/hr)2180022000
Heating at 47 °F(BTU/hr)2400022000
Heating at 17 °F(BTU/hr)1660022600
Heating at 5 °F(BTU/hr)2400016000

Configuration

SpecDaikinMDV
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesAURORAMVBM series
Indoor-Unit Combinations Rated11

Refrigerant

SpecDaikinMDV
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)

More comparisons