SpecDirectory

ECOER EODA17H-2436AD*vsZERO ZOV-36HDTB

Side-by-side heat pump comparison

ECOER EODA17H-2436AD*

SEER2

15.2–18.5BTU/Wh

HSPF2

8.1–8.8BTU/Wh

Cooling Capacity

24000–34200BTU/hr

Cold Climate

Yes

Cold climate certified

ZERO ZOV-36HDTB

SEER2

19BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

34000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

ZERO ZOV-36HDTB is 3% more efficient at 19.0 BTU/Wh versus 18.5 BTU/Wh for the ECOER EODA17H-2436AD*. The ECOER EODA17H-2436AD* is larger at 34200 BTU/hr versus 34000 BTU/hr. ZERO ZOV-36HDTB uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecECOERZERO
SEER2 (best combination)(BTU/Wh)18.519
SEER2 (worst combination)(BTU/Wh)15.219
HSPF2 (best combination)(BTU/Wh)8.89
HSPF2 (worst combination)(BTU/Wh)8.19
EER2 (best combination)(BTU/Wh)1210
COP at 5 °F21.90

Capacity

SpecECOERZERO
Cooling Capacity (max)(BTU/hr)3420034000
Cooling Capacity (min)(BTU/hr)2400034000
Heating at 47 °F(BTU/hr)3420034000
Heating at 17 °F(BTU/hr)2660025000
Heating at 5 °F(BTU/hr)2400026000

Configuration

SpecECOERZERO
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesTDi Select 2Z-MAX
Indoor-Unit Combinations Rated261

Refrigerant

SpecECOERZERO
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)