SpecDirectory

Friedrich FRP15AY42AJ2NvsGoodman GSZH504210A*

Side-by-side heat pump comparison

Friedrich FRP15AY42AJ2N

SEER2

15.2–16BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

40000BTU/hr

Cold Climate

Yes

Cold climate certified

Goodman GSZH504210A*

SEER2

15.2BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

39000–39500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Friedrich FRP15AY42AJ2N is 5% more efficient at 16.0 BTU/Wh versus 15.2 BTU/Wh for the Goodman GSZH504210A*. The Friedrich FRP15AY42AJ2N is larger at 40000 BTU/hr versus 39500 BTU/hr. Friedrich FRP15AY42AJ2N uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Friedrich FRP15AY42AJ2N sits higher in the category, ranking above 14% of certified air-source heat pumps.

Efficiency

SpecFriedrichGoodman
SEER2 (best combination)(BTU/Wh)1615.2
SEER2 (worst combination)(BTU/Wh)15.215.2
HSPF2 (best combination)(BTU/Wh)8.17.8
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1212.5
COP at 5 °F2.101.80

Capacity

SpecFriedrichGoodman
Cooling Capacity (max)(BTU/hr)4000039500
Cooling Capacity (min)(BTU/hr)4000039000
Heating at 47 °F(BTU/hr)4000039500
Heating at 17 °F(BTU/hr)4000024000
Heating at 5 °F(BTU/hr)1930019000

Configuration

SpecFriedrichGoodman
Product TypeHP - Split SystemHP - Split System
Compressor StagingTwo-stageSingle stage
Cold Climate CertifiedYesNo
Connected CapabilityNoNo
SeriesF-SERIES PLUSGSZH5
Indoor-Unit Combinations Rated1294

Refrigerant

SpecFriedrichGoodman
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)