SpecDirectory

Lennox ML16KP2-060-230A**vsMitsubishi Electric MXZ-SM60NAM***

Side-by-side heat pump comparison

Lennox ML16KP2-060-230A**

SEER2

15.5–15.8BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

57500–58500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Mitsubishi Electric MXZ-SM60NAM***

SEER2

17.8BTU/Wh

HSPF2

9.6BTU/Wh

Cooling Capacity

60000BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Key differences

Mitsubishi Electric MXZ-SM60NAM*** is 11% more efficient at 17.8 BTU/Wh versus 15.8 BTU/Wh for the Lennox ML16KP2-060-230A**. The Mitsubishi Electric MXZ-SM60NAM*** is larger at 60000 BTU/hr versus 58500 BTU/hr. Lennox ML16KP2-060-230A** uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Mitsubishi Electric MXZ-SM60NAM*** sits higher in the category, ranking above 100% of certified air-source heat pumps.

Efficiency

SpecLennoxMitsubishi Electric
SEER2 (best combination)(BTU/Wh)15.817.8
SEER2 (worst combination)(BTU/Wh)15.517.8
HSPF2 (best combination)(BTU/Wh)7.89.6
HSPF2 (worst combination)(BTU/Wh)7.89.6
EER2 (best combination)(BTU/Wh)12.211.8
COP at 5 °F2.102.07

Capacity

SpecLennoxMitsubishi Electric
Cooling Capacity (max)(BTU/hr)5850060000
Cooling Capacity (min)(BTU/hr)5750060000
Heating at 47 °F(BTU/hr)5450064500
Heating at 17 °F(BTU/hr)3420041000
Heating at 5 °F(BTU/hr)2780044500

Configuration

SpecLennoxMitsubishi Electric
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesMerit ML16KP2 SERIESSmart Multi
Indoor-Unit Combinations Rated21

Refrigerant

SpecLennoxMitsubishi Electric
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)