Lennox ML16KP2-060-230A**vsMitsubishi Electric PUMY-P60NKMU3***

Side-by-side heat pump comparison

Lennox ML16KP2-060-230A**

SEER2

15.5–15.8BTU/Wh

HSPF2

7.8BTU/Wh

Cooling Capacity

57500–58500BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Mitsubishi Electric PUMY-P60NKMU3***

SEER2

15.5–20BTU/Wh

HSPF2

8.6–10.5BTU/Wh

Cooling Capacity

60000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Mitsubishi Electric PUMY-P60NKMU3*** is 21% more efficient at 20.0 BTU/Wh versus 15.8 BTU/Wh for the Lennox ML16KP2-060-230A**. The Mitsubishi Electric PUMY-P60NKMU3*** is larger at 60000 BTU/hr versus 58500 BTU/hr. Lennox ML16KP2-060-230A** uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the Mitsubishi Electric PUMY-P60NKMU3*** sits higher in the category, ranking above 100% of certified air-source heat pumps.

Efficiency

SpecLennoxMitsubishi Electric
SEER2 (best combination)(BTU/Wh)15.820
SEER2 (worst combination)(BTU/Wh)15.515.5
HSPF2 (best combination)(BTU/Wh)7.810.5
HSPF2 (worst combination)(BTU/Wh)7.88.6
EER2 (best combination)(BTU/Wh)12.213.3
COP at 5 °F2.102

Capacity

SpecLennoxMitsubishi Electric
Cooling Capacity (max)(BTU/hr)5850060000
Cooling Capacity (min)(BTU/hr)5750060000
Heating at 47 °F(BTU/hr)5450064500
Heating at 17 °F(BTU/hr)3420041500
Heating at 5 °F(BTU/hr)2780057000

Configuration

SpecLennoxMitsubishi Electric
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingTwo-stageContinuously variable
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
SeriesMerit ML16KP2 SERIESS-Series
Indoor-Unit Combinations Rated22

Refrigerant

SpecLennoxMitsubishi Electric
TypeR-454BR-410A
GWP RatingR-454B (GWP:470 | Lower GWP)R-410A (GWP:2088)