LG KUSUB601AvsLuxaire XDV60E2D11

Side-by-side heat pump comparison

LG KUSUB601A

SEER2

18.5BTU/Wh

HSPF2

9BTU/Wh

Cooling Capacity

52500BTU/hr

Cold Climate

Yes

Cold climate certified

Luxaire XDV60E2D11

SEER2

18–18.5BTU/Wh

HSPF2

9.5BTU/Wh

Cooling Capacity

47000–52000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

The LG KUSUB601A is larger at 52500 BTU/hr versus 52000 BTU/hr. Luxaire XDV60E2D11 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-32 (GWP 675).

Efficiency

SpecLGLuxaire
SEER2 (best combination)(BTU/Wh)18.518.5
SEER2 (worst combination)(BTU/Wh)18.518
HSPF2 (best combination)(BTU/Wh)99.5
HSPF2 (worst combination)(BTU/Wh)99.5
EER2 (best combination)(BTU/Wh)1112
COP at 5 °F1.852

Capacity

SpecLGLuxaire
Cooling Capacity (max)(BTU/hr)5250052000
Cooling Capacity (min)(BTU/hr)5250047000
Heating at 47 °F(BTU/hr)5500055000
Heating at 17 °F(BTU/hr)3480044000
Heating at 5 °F(BTU/hr)3850038500

Configuration

SpecLGLuxaire
Product TypeHP - Mini or Multi SplitHP - Split System
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoYes
SeriesKUSUB601AXDV
Indoor-Unit Combinations Rated12

Refrigerant

SpecLGLuxaire
TypeR-32R-454B
GWP RatingR-32 (GWP:675 | Lower GWP)R-454B (GWP:470 | Lower GWP)