SpecDirectory

MDV M3OH-27HFN1-MQ1vsMDV M3OX430-27HFN8-M1

Side-by-side heat pump comparison

MDV M3OH-27HFN1-MQ1

SEER2

20.8–22BTU/Wh

HSPF2

9.3–9.5BTU/Wh

Cooling Capacity

27000–27400BTU/hr

Cold Climate

Yes

Cold climate certified

MDV M3OX430-27HFN8-M1

SEER2

18.1–22.5BTU/Wh

HSPF2

9–10BTU/Wh

Cooling Capacity

27000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

Both models are closely matched on seer2: 22.0 vs 22.5 BTU/Wh. The MDV M3OH-27HFN1-MQ1 is larger at 27400 BTU/hr versus 27000 BTU/hr. MDV M3OX430-27HFN8-M1 uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecMDVMDV
SEER2 (best combination)(BTU/Wh)2222.5
SEER2 (worst combination)(BTU/Wh)20.818.1
HSPF2 (best combination)(BTU/Wh)9.510
HSPF2 (worst combination)(BTU/Wh)9.39
EER2 (best combination)(BTU/Wh)1212.5
COP at 5 °F1.902.80

Capacity

SpecMDVMDV
Cooling Capacity (max)(BTU/hr)2740027000
Cooling Capacity (min)(BTU/hr)2700027000
Heating at 47 °F(BTU/hr)2740027000
Heating at 17 °F(BTU/hr)2040021000
Heating at 5 °F(BTU/hr)1900021400

Configuration

SpecMDVMDV
Product TypeHP - Mini or Multi SplitHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityNoNo
SeriesMSAB seriesM3O Series
Indoor-Unit Combinations Rated23

Refrigerant

SpecMDVMDV
TypeR-410AR-32
GWP RatingR-410A (GWP:2088)R-32 (GWP:675 | Lower GWP)