AC PRO 4HP18V60PvsAmerican Standard 5HPL5048A1000AA

Side-by-side heat pump comparison

AC PRO 4HP18V60P

SEER2

16–17.1BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

46000–46500BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

American Standard 5HPL5048A1000AA

SEER2

16BTU/Wh

HSPF2

8.1BTU/Wh

Cooling Capacity

46000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

AC PRO 4HP18V60P is 6% more efficient at 17.1 BTU/Wh versus 16.0 BTU/Wh for the American Standard 5HPL5048A1000AA. The AC PRO 4HP18V60P is larger at 46500 BTU/hr versus 46000 BTU/hr. American Standard 5HPL5048A1000AA uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088). Overall, the AC PRO 4HP18V60P sits higher in the category, ranking above 83% of certified air-source heat pumps.

Efficiency

SpecAC PROAmerican Standard
SEER2 (best combination)(BTU/Wh)17.116
SEER2 (worst combination)(BTU/Wh)1616
HSPF2 (best combination)(BTU/Wh)8.58.1
HSPF2 (worst combination)(BTU/Wh)7.88.1
EER2 (best combination)(BTU/Wh)11.711.7
COP at 5 °F2.101.75

Capacity

SpecAC PROAmerican Standard
Cooling Capacity (max)(BTU/hr)4650046000
Cooling Capacity (min)(BTU/hr)4600046000
Heating at 47 °F(BTU/hr)4650048000
Heating at 17 °F(BTU/hr)3600042000
Heating at 5 °F(BTU/hr)2880038000

Configuration

SpecAC PROAmerican Standard
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableTwo-stage
Cold Climate CertifiedNoYes
Connected CapabilityNoNo
Series4HP18V SERIES5HPL5
Indoor-Unit Combinations Rated201

Refrigerant

SpecAC PROAmerican Standard
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)