SpecDirectory

Amana AZV6SA1810A*vsGE Appliances ASH118PRDB**

Side-by-side heat pump comparison

Amana AZV6SA1810A*

SEER2

16–19BTU/Wh

HSPF2

8.5–8.8BTU/Wh

Cooling Capacity

17000–17100BTU/hr

Cold Climate

Yes

Cold climate certified

GE Appliances ASH118PRDB**

SEER2

21BTU/Wh

HSPF2

9.6BTU/Wh

Cooling Capacity

17000BTU/hr

Cold Climate

Yes

Cold climate certified

Key differences

GE Appliances ASH118PRDB** is 10% more efficient at 21.0 BTU/Wh versus 19.0 BTU/Wh for the Amana AZV6SA1810A*. The Amana AZV6SA1810A* is larger at 17100 BTU/hr versus 17000 BTU/hr. Amana AZV6SA1810A* uses a lower-impact refrigerant: R-32 (GWP 675) versus R-410A (GWP 2088).

Efficiency

SpecAmanaGE Appliances
SEER2 (best combination)(BTU/Wh)1921
SEER2 (worst combination)(BTU/Wh)1621
HSPF2 (best combination)(BTU/Wh)8.89.6
HSPF2 (worst combination)(BTU/Wh)8.59.6
EER2 (best combination)(BTU/Wh)1212.5
COP at 5 °F2.101.80

Capacity

SpecAmanaGE Appliances
Cooling Capacity (max)(BTU/hr)1710017000
Cooling Capacity (min)(BTU/hr)1700017000
Heating at 47 °F(BTU/hr)1740021000
Heating at 17 °F(BTU/hr)1080013600
Heating at 5 °F(BTU/hr)1300015400

Configuration

SpecAmanaGE Appliances
Product TypeHP - Split SystemHP - Mini or Multi Split
Compressor StagingContinuously variableContinuously variable
Cold Climate CertifiedYesYes
Connected CapabilityYesNo
SeriesAZV6SAAltitude
Indoor-Unit Combinations Rated731

Refrigerant

SpecAmanaGE Appliances
TypeR-32R-410A
GWP RatingR-32 (GWP:675 | Lower GWP)R-410A (GWP:2088)

More comparisons