SpecDirectory

Trane 4TWV7X36A1vsTrane 5TWX6036A1

Side-by-side heat pump comparison

Trane 4TWV7X36A1

SEER2

17–17.1BTU/Wh

HSPF2

7.8–8.5BTU/Wh

Cooling Capacity

33600–35600BTU/hr

Refrigerant

R-410A

GWP 2088 · Higher

Trane 5TWX6036A1

SEER2

15.2–16.5BTU/Wh

HSPF2

7.8–8.1BTU/Wh

Cooling Capacity

32000–35400BTU/hr

Refrigerant

R-454B

GWP 470 · Lower

Key differences

Trane 4TWV7X36A1 is 4% more efficient at 17.1 BTU/Wh versus 16.5 BTU/Wh for the Trane 5TWX6036A1. The Trane 4TWV7X36A1 is larger at 35600 BTU/hr versus 35400 BTU/hr. Trane 5TWX6036A1 uses a lower-impact refrigerant: R-454B (GWP 470) versus R-410A (GWP 2088).

Efficiency

SpecTraneTrane
SEER2 (best combination)(BTU/Wh)17.116.5
SEER2 (worst combination)(BTU/Wh)1715.2
HSPF2 (best combination)(BTU/Wh)8.58.1
HSPF2 (worst combination)(BTU/Wh)7.87.8
EER2 (best combination)(BTU/Wh)1212
COP at 5 °F1.902.48

Capacity

SpecTraneTrane
Cooling Capacity (max)(BTU/hr)3560035400
Cooling Capacity (min)(BTU/hr)3360032000
Heating at 47 °F(BTU/hr)3600032400
Heating at 17 °F(BTU/hr)2680022200
Heating at 5 °F(BTU/hr)2100017700

Configuration

SpecTraneTrane
Product TypeHP - Split SystemHP - Split System
Compressor StagingContinuously variableSingle stage
Cold Climate CertifiedNoNo
Connected CapabilityNoNo
SeriesXV1716 Single-Stage Heat Pump with WeatherGuard Top
Indoor-Unit Combinations Rated144374

Refrigerant

SpecTraneTrane
TypeR-410AR-454B
GWP RatingR-410A (GWP:2088)R-454B (GWP:470 | Lower GWP)

More comparisons